Generic resistive touchscreen ADC
|
|
|
|
Required properties:
|
|
|
|
- compatible: must be "resistive-adc-touch"
|
|
The device must be connected to an ADC device that provides channels for
|
|
position measurement and optional pressure.
|
|
Refer to ../iio/iio-bindings.txt for details
|
|
- iio-channels: must have at least two channels connected to an ADC device.
|
|
These should correspond to the channels exposed by the ADC device and should
|
|
have the right index as the ADC device registers them. These channels
|
|
represent the relative position on the "x" and "y" axes.
|
|
- iio-channel-names: must have all the channels' names. Mandatory channels
|
|
are "x" and "y".
|
|
|
|
Optional properties:
|
|
- iio-channels: The third channel named "pressure" is optional and can be
|
|
used if the ADC device also measures pressure besides position.
|
|
If this channel is missing, pressure will be ignored and the touchscreen
|
|
will only report position.
|
|
- iio-channel-names: optional channel named "pressure".
|
|
|
|
Example:
|
|
|
|
resistive_touch: resistive_touch {
|
|
compatible = "resistive-adc-touch";
|
|
touchscreen-min-pressure = <50000>;
|
|
io-channels = <&adc 24>, <&adc 25>, <&adc 26>;
|
|
io-channel-names = "x", "y", "pressure";
|
|
};
|