Maxim MAX31856 thermocouple support
|
|
|
|
https://datasheets.maximintegrated.com/en/ds/MAX31856.pdf
|
|
|
|
Optional property:
|
|
- thermocouple-type: Type of thermocouple (THERMOCOUPLE_TYPE_K if
|
|
omitted). Supported types are B, E, J, K, N, R, S, T.
|
|
|
|
Required properties:
|
|
- compatible: must be "maxim,max31856"
|
|
- reg: SPI chip select number for the device
|
|
- spi-max-frequency: As per datasheet max. supported freq is 5000000
|
|
- spi-cpha: must be defined for max31856 to enable SPI mode 1
|
|
|
|
Refer to spi/spi-bus.txt for generic SPI slave bindings.
|
|
|
|
Example:
|
|
temp-sensor@0 {
|
|
compatible = "maxim,max31856";
|
|
reg = <0>;
|
|
spi-max-frequency = <5000000>;
|
|
spi-cpha;
|
|
thermocouple-type = <THERMOCOUPLE_TYPE_K>;
|
|
};
|