linux/linux-5.4.31/Documentation/devicetree/bindings/thermal/brcm,ns-thermal.txt

38 lines
716 B
Plaintext
Raw Normal View History

2024-01-30 10:43:28 +00:00
* Broadcom Northstar Thermal
This binding describes thermal sensor that is part of Northstar's DMU (Device
Management Unit).
Required properties:
- compatible : Must be "brcm,ns-thermal"
- reg : iomem address range of PVTMON registers
- #thermal-sensor-cells : Should be <0>
Example:
thermal: thermal@1800c2c0 {
compatible = "brcm,ns-thermal";
reg = <0x1800c2c0 0x10>;
#thermal-sensor-cells = <0>;
};
thermal-zones {
cpu_thermal: cpu-thermal {
polling-delay-passive = <0>;
polling-delay = <1000>;
coefficients = <(-556) 418000>;
thermal-sensors = <&thermal>;
trips {
cpu-crit {
temperature = <125000>;
hysteresis = <0>;
type = "critical";
};
};
cooling-maps {
};
};
};