Kernel driver max15301
|
|
======================
|
|
|
|
Supported chips:
|
|
|
|
* Maxim MAX15301
|
|
|
|
Prefix: 'max15301', 'bmr461'
|
|
|
|
Addresses scanned: -
|
|
|
|
Datasheet: https://datasheets.maximintegrated.com/en/ds/MAX15301.pdf
|
|
|
|
Author: Erik Rosen <erik.rosen@metormote.com>
|
|
|
|
|
|
Description
|
|
-----------
|
|
|
|
This driver supports hardware monitoring for Maxim MAX15301 controller chip and
|
|
compatible modules.
|
|
|
|
The driver is a client driver to the core PMBus driver. Please see
|
|
Documentation/hwmon/pmbus.rst and Documentation.hwmon/pmbus-core for details
|
|
on PMBus client drivers.
|
|
|
|
|
|
Usage Notes
|
|
-----------
|
|
|
|
This driver does not auto-detect devices. You will have to instantiate the
|
|
devices explicitly. Please see Documentation/i2c/instantiating-devices.rst for
|
|
details.
|
|
|
|
|
|
Platform data support
|
|
---------------------
|
|
|
|
The driver supports standard PMBus driver platform data.
|
|
|
|
|
|
Module parameters
|
|
-----------------
|
|
|
|
delay
|
|
-----
|
|
|
|
The controller requires a minimum interval between I2C bus accesses.
|
|
The default interval is set to 100 us. For manual override, the driver
|
|
provides a writeable module parameter, 'delay', which can be used to
|
|
set the interval to a value between 0 and 65,535 microseconds.
|
|
|
|
|
|
Sysfs entries
|
|
-------------
|
|
|
|
The following attributes are supported. Limits are read-write; all other
|
|
attributes are read-only.
|
|
|
|
======================= ========================================================
|
|
in1_label "vin"
|
|
in1_input Measured input voltage.
|
|
in1_lcrit Critical minimum input voltage.
|
|
in1_crit Critical maximum input voltage.
|
|
in1_lcrit_alarm Input voltage critical low alarm.
|
|
in1_crit_alarm Input voltage critical high alarm.
|
|
|
|
in2_label "vout1"
|
|
in2_input Measured output voltage.
|
|
in2_lcrit Critical minimum output Voltage.
|
|
in2_crit Critical maximum output voltage.
|
|
in2_lcrit_alarm Critical output voltage critical low alarm.
|
|
in2_crit_alarm Critical output voltage critical high alarm.
|
|
|
|
curr1_label "iout1"
|
|
curr1_input Measured output current.
|
|
curr1_crit Critical maximum output current.
|
|
curr1_crit_alarm Output current critical high alarm.
|
|
|
|
temp1_input Measured maximum temperature of all phases.
|
|
temp1_max Maximum temperature limit.
|
|
temp1_max_alarm High temperature alarm.
|
|
temp1_crit Critical maximum temperature limit.
|
|
temp1_crit_alarm Critical maximum temperature alarm.
|
|
======================= ========================================================
|