.. SPDX-License-Identifier: GPL-2.0
|
||
|
|
||
|
Kernel driver drivetemp
|
||
|
=======================
|
||
|
|
||
|
|
||
|
References
|
||
|
----------
|
||
|
|
||
|
ANS T13/1699-D
|
||
|
Information technology - AT Attachment 8 - ATA/ATAPI Command Set (ATA8-ACS)
|
||
|
|
||
|
ANS Project T10/BSR INCITS 513
|
||
|
Information technology - SCSI Primary Commands - 4 (SPC-4)
|
||
|
|
||
|
ANS Project INCITS 557
|
||
|
Information technology - SCSI / ATA Translation - 5 (SAT-5)
|
||
|
|
||
|
|
||
|
Description
|
||
|
-----------
|
||
|
|
||
|
This driver supports reporting the temperature of disk and solid state
|
||
|
drives with temperature sensors.
|
||
|
|
||
|
If supported, it uses the ATA SCT Command Transport feature to read
|
||
|
the current drive temperature and, if available, temperature limits
|
||
|
as well as historic minimum and maximum temperatures. If SCT Command
|
||
|
Transport is not supported, the driver uses SMART attributes to read
|
||
|
the drive temperature.
|
||
|
|
||
|
|
||
|
Usage Note
|
||
|
----------
|
||
|
|
||
|
Reading the drive temperature may reset the spin down timer on some drives.
|
||
|
This has been observed with WD120EFAX drives, but may be seen with other
|
||
|
drives as well. The same behavior is observed if the 'hdtemp' or 'smartd'
|
||
|
tools are used to access the drive.
|
||
|
With the WD120EFAX drive, reading the drive temperature using the drivetemp
|
||
|
driver is still possible _after_ it transitioned to standby mode, and
|
||
|
reading the drive temperature in this mode will not cause the drive to
|
||
|
change its mode (meaning the drive will not spin up). It is unknown if other
|
||
|
drives experience similar behavior.
|
||
|
|
||
|
A known workaround for WD120EFAX drives is to read the drive temperature at
|
||
|
intervals larger than twice the spin-down time. Otherwise affected drives
|
||
|
will never spin down.
|
||
|
|
||
|
|
||
|
Sysfs entries
|
||
|
-------------
|
||
|
|
||
|
Only the temp1_input attribute is always available. Other attributes are
|
||
|
available only if reported by the drive. All temperatures are reported in
|
||
|
milli-degrees Celsius.
|
||
|
|
||
|
======================= =====================================================
|
||
|
temp1_input Current drive temperature
|
||
|
temp1_lcrit Minimum temperature limit. Operating the device below
|
||
|
this temperature may cause physical damage to the
|
||
|
device.
|
||
|
temp1_min Minimum recommended continuous operating limit
|
||
|
temp1_max Maximum recommended continuous operating temperature
|
||
|
temp1_crit Maximum temperature limit. Operating the device above
|
||
|
this temperature may cause physical damage to the
|
||
|
device.
|
||
|
temp1_lowest Minimum temperature seen this power cycle
|
||
|
temp1_highest Maximum temperature seen this power cycle
|
||
|
======================= =====================================================
|