* Thermal device driver for DA9062 and DA9061
|
|
* Copyright (C) 2017 Dialog Semiconductor
|
|
*
|
|
* This program is free software; you can redistribute it and/or
|
|
* modify it under the terms of the GNU General Public License
|
|
* as published by the Free Software Foundation; either version 2
|
|
* of the License, or (at your option) any later version.
|
|
*
|
|
* This program is distributed in the hope that it will be useful,
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*/
|
|
|
|
/* When over-temperature is reached, an interrupt from the device will be
|
|
* triggered. Following this event the interrupt will be disabled and
|
|
* periodic transmission of uevents (HOT trip point) should define the
|
|
* first level of temperature supervision. It is expected that any final
|
|
* implementation of the thermal driver will include a .notify() function
|
|
* to implement these uevents to userspace.
|
|
*
|
|
* These uevents are intended to indicate non-invasive temperature control
|
|
* of the system, where the necessary measures for cooling are the
|
|
* responsibility of the host software. Once the temperature falls again,
|
|
* the IRQ is re-enabled so the start of a new over-temperature event can
|
|
* be detected without constant software monitoring.
|
|
*/
|
|
|
|
#include <linux/errno.h>
|
|
#include <linux/interrupt.h>
|
|
#include <linux/module.h>
|
|
#include <linux/of.h>
|
|
#include <linux/platform_device.h>
|
|
#include <linux/regmap.h>
|
|
#include <linux/thermal.h>
|
|
#include <linux/workqueue.h>
|
|
|
|
#include <linux/mfd/da9062/core.h>
|
|
#include <linux/mfd/da9062/registers.h>
|
|
|
|
/* Minimum, maximum and default polling millisecond periods are provided
|
|
* here as an example. It is expected that any final implementation to also
|
|
* include a modification of these settings to match the required
|
|
* application.
|
|
*/
|
|
#define DA9062_DEFAULT_POLLING_MS_PERIOD 3000
|
|
#define DA9062_MAX_POLLING_MS_PERIOD 10000
|
|
#define DA9062_MIN_POLLING_MS_PERIOD 1000
|
|
|
|
#define DA9062_MILLI_CELSIUS(t) ((t) * 1000)
|
|
|
|
struct da9062_thermal_config {
|
|
const char *name;
|
|
};
|
|
|
|
struct da9062_thermal {
|
|
struct da9062 *hw;
|
|
struct delayed_work work;
|
|
struct thermal_zone_device *zone;
|
|
enum thermal_device_mode mode;
|
|
struct mutex lock; /* protection for da9062_thermal temperature */
|
|
int temperature;
|
|
int irq;
|
|
const struct da9062_thermal_config *config;
|
|
struct device *dev;
|
|
};
|
|
|
|
static void da9062_thermal_poll_on(struct work_struct *work)
|
|
{
|
|
struct da9062_thermal *thermal = container_of(work,
|
|
struct da9062_thermal,
|
|
work.work);
|
|
unsigned long delay;
|
|
unsigned int val;
|
|
int ret;
|
|
|
|
/* clear E_TEMP */
|
|
ret = regmap_write(thermal->hw->regmap,
|
|
DA9062AA_EVENT_B,
|
|
DA9062AA_E_TEMP_MASK);
|
|
if (ret < 0) {
|
|
dev_err(thermal->dev,
|
|
"Cannot clear the TJUNC temperature status\n");
|
|
goto err_enable_irq;
|
|
}
|
|
|
|
/* Now read E_TEMP again: it is acting like a status bit.
|
|
* If over-temperature, then this status will be true.
|
|
* If not over-temperature, this status will be false.
|
|
*/
|
|
ret = regmap_read(thermal->hw->regmap,
|
|
DA9062AA_EVENT_B,
|
|
&val);
|
|
if (ret < 0) {
|
|
dev_err(thermal->dev,
|
|
"Cannot check the TJUNC temperature status\n");
|
|
goto err_enable_irq;
|
|
}
|
|
|
|
if (val & DA9062AA_E_TEMP_MASK) {
|
|
mutex_lock(&thermal->lock);
|
|
thermal->temperature = DA9062_MILLI_CELSIUS(125);
|
|
mutex_unlock(&thermal->lock);
|
|
thermal_zone_device_update(thermal->zone,
|
|
THERMAL_EVENT_UNSPECIFIED);
|
|
|
|
delay = msecs_to_jiffies(thermal->zone->passive_delay);
|
|
schedule_delayed_work(&thermal->work, delay);
|
|
return;
|
|
}
|
|
|
|
mutex_lock(&thermal->lock);
|
|
thermal->temperature = DA9062_MILLI_CELSIUS(0);
|
|
mutex_unlock(&thermal->lock);
|
|
thermal_zone_device_update(thermal->zone,
|
|
THERMAL_EVENT_UNSPECIFIED);
|
|
|
|
err_enable_irq:
|
|
enable_irq(thermal->irq);
|
|
}
|
|
|
|
static irqreturn_t da9062_thermal_irq_handler(int irq, void *data)
|
|
{
|
|
struct da9062_thermal *thermal = data;
|
|
|
|
disable_irq_nosync(thermal->irq);
|
|
schedule_delayed_work(&thermal->work, 0);
|
|
|
|
return IRQ_HANDLED;
|
|
}
|
|
|
|
static int da9062_thermal_get_mode(struct thermal_zone_device *z,
|
|
enum thermal_device_mode *mode)
|
|
{
|
|
struct da9062_thermal *thermal = z->devdata;
|
|
*mode = thermal->mode;
|
|
return 0;
|
|
}
|
|
|
|
static int da9062_thermal_get_trip_type(struct thermal_zone_device *z,
|
|
int trip,
|
|
enum thermal_trip_type *type)
|
|
{
|
|
struct da9062_thermal *thermal = z->devdata;
|
|
|
|
switch (trip) {
|
|
case 0:
|
|
*type = THERMAL_TRIP_HOT;
|
|
break;
|
|
default:
|
|
dev_err(thermal->dev,
|
|
"Driver does not support more than 1 trip-wire\n");
|
|
return -EINVAL;
|
|
}
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int da9062_thermal_get_trip_temp(struct thermal_zone_device *z,
|
|
int trip,
|
|
int *temp)
|
|
{
|
|
struct da9062_thermal *thermal = z->devdata;
|
|
|
|
switch (trip) {
|
|
case 0:
|
|
*temp = DA9062_MILLI_CELSIUS(125);
|
|
break;
|
|
default:
|
|
dev_err(thermal->dev,
|
|
"Driver does not support more than 1 trip-wire\n");
|
|
return -EINVAL;
|
|
}
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int da9062_thermal_get_temp(struct thermal_zone_device *z,
|
|
int *temp)
|
|
{
|
|
struct da9062_thermal *thermal = z->devdata;
|
|
|
|
mutex_lock(&thermal->lock);
|
|
*temp = thermal->temperature;
|
|
mutex_unlock(&thermal->lock);
|
|
|
|
return 0;
|
|
}
|
|
|
|
static struct thermal_zone_device_ops da9062_thermal_ops = {
|
|
.get_temp = da9062_thermal_get_temp,
|
|
.get_mode = da9062_thermal_get_mode,
|
|
.get_trip_type = da9062_thermal_get_trip_type,
|
|
.get_trip_temp = da9062_thermal_get_trip_temp,
|
|
};
|
|
|
|
static const struct da9062_thermal_config da9062_config = {
|
|
.name = "da9062-thermal",
|
|
};
|
|
|
|
static const struct of_device_id da9062_compatible_reg_id_table[] = {
|
|
{ .compatible = "dlg,da9062-thermal", .data = &da9062_config },
|
|
{ },
|
|
};
|
|
|
|
MODULE_DEVICE_TABLE(of, da9062_compatible_reg_id_table);
|
|
|
|
static int da9062_thermal_probe(struct platform_device *pdev)
|
|
{
|
|
struct da9062 *chip = dev_get_drvdata(pdev->dev.parent);
|
|
struct da9062_thermal *thermal;
|
|
unsigned int pp_tmp = DA9062_DEFAULT_POLLING_MS_PERIOD;
|
|
const struct of_device_id *match;
|
|
int ret = 0;
|
|
|
|
match = of_match_node(da9062_compatible_reg_id_table,
|
|
pdev->dev.of_node);
|
|
if (!match)
|
|
return -ENXIO;
|
|
|
|
if (pdev->dev.of_node) {
|
|
if (!of_property_read_u32(pdev->dev.of_node,
|
|
"polling-delay-passive",
|
|
&pp_tmp)) {
|
|
if (pp_tmp < DA9062_MIN_POLLING_MS_PERIOD ||
|
|
pp_tmp > DA9062_MAX_POLLING_MS_PERIOD) {
|
|
dev_warn(&pdev->dev,
|
|
"Out-of-range polling period %d ms\n",
|
|
pp_tmp);
|
|
pp_tmp = DA9062_DEFAULT_POLLING_MS_PERIOD;
|
|
}
|
|
}
|
|
}
|
|
|
|
thermal = devm_kzalloc(&pdev->dev, sizeof(struct da9062_thermal),
|
|
GFP_KERNEL);
|
|
if (!thermal) {
|
|
ret = -ENOMEM;
|
|
goto err;
|
|
}
|
|
|
|
thermal->config = match->data;
|
|
thermal->hw = chip;
|
|
thermal->mode = THERMAL_DEVICE_ENABLED;
|
|
thermal->dev = &pdev->dev;
|
|
|
|
INIT_DELAYED_WORK(&thermal->work, da9062_thermal_poll_on);
|
|
mutex_init(&thermal->lock);
|
|
|
|
thermal->zone = thermal_zone_device_register(thermal->config->name,
|
|
1, 0, thermal,
|
|
&da9062_thermal_ops, NULL, pp_tmp,
|
|
0);
|
|
if (IS_ERR(thermal->zone)) {
|
|
dev_err(&pdev->dev, "Cannot register thermal zone device\n");
|
|
ret = PTR_ERR(thermal->zone);
|
|
goto err;
|
|
}
|
|
|
|
dev_dbg(&pdev->dev,
|
|
"TJUNC temperature polling period set at %d ms\n",
|
|
thermal->zone->passive_delay);
|
|
|
|
ret = platform_get_irq_byname(pdev, "THERMAL");
|
|
if (ret < 0) {
|
|
dev_err(&pdev->dev, "Failed to get platform IRQ.\n");
|
|
goto err_zone;
|
|
}
|
|
thermal->irq = ret;
|
|
|
|
ret = request_threaded_irq(thermal->irq, NULL,
|
|
da9062_thermal_irq_handler,
|
|
IRQF_TRIGGER_LOW | IRQF_ONESHOT,
|
|
"THERMAL", thermal);
|
|
if (ret) {
|
|
dev_err(&pdev->dev,
|
|
"Failed to request thermal device IRQ.\n");
|
|
goto err_zone;
|
|
}
|
|
|
|
platform_set_drvdata(pdev, thermal);
|
|
return 0;
|
|
|
|
err_zone:
|
|
thermal_zone_device_unregister(thermal->zone);
|
|
err:
|
|
return ret;
|
|
}
|
|
|
|
static int da9062_thermal_remove(struct platform_device *pdev)
|
|
{
|
|
struct da9062_thermal *thermal = platform_get_drvdata(pdev);
|
|
|
|
free_irq(thermal->irq, thermal);
|
|
cancel_delayed_work_sync(&thermal->work);
|
|
thermal_zone_device_unregister(thermal->zone);
|
|
return 0;
|
|
}
|
|
|
|
static struct platform_driver da9062_thermal_driver = {
|
|
.probe = da9062_thermal_probe,
|
|
.remove = da9062_thermal_remove,
|
|
.driver = {
|
|
.name = "da9062-thermal",
|
|
.of_match_table = da9062_compatible_reg_id_table,
|
|
},
|
|
};
|
|
|
|
module_platform_driver(da9062_thermal_driver);
|
|
|
|
MODULE_AUTHOR("Steve Twiss");
|
|
MODULE_DESCRIPTION("Thermal TJUNC device driver for Dialog DA9062 and DA9061");
|
|
MODULE_LICENSE("GPL");
|
|
MODULE_ALIAS("platform:da9062-thermal");
|