154 lines
4.4 KiB
C
154 lines
4.4 KiB
C
/*
|
|
* Amlogic Meson GXL Internal PHY Driver
|
|
*
|
|
* Copyright (C) 2015 Amlogic, Inc. All rights reserved.
|
|
* Copyright (C) 2016 BayLibre, SAS. All rights reserved.
|
|
* Author: Neil Armstrong <narmstrong@baylibre.com>
|
|
*
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License as published by
|
|
* the Free Software Foundation; either version 2 of the License, or
|
|
* (at your option) any later version.
|
|
*
|
|
* This program is distributed in the hope that it will be useful, but WITHOUT
|
|
* ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or
|
|
* FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for
|
|
* more details.
|
|
*
|
|
*/
|
|
#include <linux/kernel.h>
|
|
#include <linux/module.h>
|
|
#include <linux/mii.h>
|
|
#include <linux/ethtool.h>
|
|
#include <linux/phy.h>
|
|
#include <linux/netdevice.h>
|
|
#include <linux/bitfield.h>
|
|
|
|
static int meson_gxl_config_init(struct phy_device *phydev)
|
|
{
|
|
/* Enable Analog and DSP register Bank access by */
|
|
phy_write(phydev, 0x14, 0x0000);
|
|
phy_write(phydev, 0x14, 0x0400);
|
|
phy_write(phydev, 0x14, 0x0000);
|
|
phy_write(phydev, 0x14, 0x0400);
|
|
|
|
/* Write Analog register 23 */
|
|
phy_write(phydev, 0x17, 0x8E0D);
|
|
phy_write(phydev, 0x14, 0x4417);
|
|
|
|
/* Enable fractional PLL */
|
|
phy_write(phydev, 0x17, 0x0005);
|
|
phy_write(phydev, 0x14, 0x5C1B);
|
|
|
|
/* Program fraction FR_PLL_DIV1 */
|
|
phy_write(phydev, 0x17, 0x029A);
|
|
phy_write(phydev, 0x14, 0x5C1D);
|
|
|
|
/* Program fraction FR_PLL_DIV1 */
|
|
phy_write(phydev, 0x17, 0xAAAA);
|
|
phy_write(phydev, 0x14, 0x5C1C);
|
|
|
|
return 0;
|
|
}
|
|
|
|
/* This function is provided to cope with the possible failures of this phy
|
|
* during aneg process. When aneg fails, the PHY reports that aneg is done
|
|
* but the value found in MII_LPA is wrong:
|
|
* - Early failures: MII_LPA is just 0x0001. if MII_EXPANSION reports that
|
|
* the link partner (LP) supports aneg but the LP never acked our base
|
|
* code word, it is likely that we never sent it to begin with.
|
|
* - Late failures: MII_LPA is filled with a value which seems to make sense
|
|
* but it actually is not what the LP is advertising. It seems that we
|
|
* can detect this using a magic bit in the WOL bank (reg 12 - bit 12).
|
|
* If this particular bit is not set when aneg is reported being done,
|
|
* it means MII_LPA is likely to be wrong.
|
|
*
|
|
* In both case, forcing a restart of the aneg process solve the problem.
|
|
* When this failure happens, the first retry is usually successful but,
|
|
* in some cases, it may take up to 6 retries to get a decent result
|
|
*/
|
|
static int meson_gxl_read_status(struct phy_device *phydev)
|
|
{
|
|
int ret, wol, lpa, exp;
|
|
|
|
if (phydev->autoneg == AUTONEG_ENABLE) {
|
|
ret = genphy_aneg_done(phydev);
|
|
if (ret < 0)
|
|
return ret;
|
|
else if (!ret)
|
|
goto read_status_continue;
|
|
|
|
/* Need to access WOL bank, make sure the access is open */
|
|
ret = phy_write(phydev, 0x14, 0x0000);
|
|
if (ret)
|
|
return ret;
|
|
ret = phy_write(phydev, 0x14, 0x0400);
|
|
if (ret)
|
|
return ret;
|
|
ret = phy_write(phydev, 0x14, 0x0000);
|
|
if (ret)
|
|
return ret;
|
|
ret = phy_write(phydev, 0x14, 0x0400);
|
|
if (ret)
|
|
return ret;
|
|
|
|
/* Request LPI_STATUS WOL register */
|
|
ret = phy_write(phydev, 0x14, 0x8D80);
|
|
if (ret)
|
|
return ret;
|
|
|
|
/* Read LPI_STATUS value */
|
|
wol = phy_read(phydev, 0x15);
|
|
if (wol < 0)
|
|
return wol;
|
|
|
|
lpa = phy_read(phydev, MII_LPA);
|
|
if (lpa < 0)
|
|
return lpa;
|
|
|
|
exp = phy_read(phydev, MII_EXPANSION);
|
|
if (exp < 0)
|
|
return exp;
|
|
|
|
if (!(wol & BIT(12)) ||
|
|
((exp & EXPANSION_NWAY) && !(lpa & LPA_LPACK))) {
|
|
/* Looks like aneg failed after all */
|
|
phydev_dbg(phydev, "LPA corruption - aneg restart\n");
|
|
return genphy_restart_aneg(phydev);
|
|
}
|
|
}
|
|
|
|
read_status_continue:
|
|
return genphy_read_status(phydev);
|
|
}
|
|
|
|
static struct phy_driver meson_gxl_phy[] = {
|
|
{
|
|
.phy_id = 0x01814400,
|
|
.phy_id_mask = 0xfffffff0,
|
|
.name = "Meson GXL Internal PHY",
|
|
.features = PHY_BASIC_FEATURES,
|
|
.flags = PHY_IS_INTERNAL,
|
|
.config_init = meson_gxl_config_init,
|
|
.config_aneg = genphy_config_aneg,
|
|
.aneg_done = genphy_aneg_done,
|
|
.read_status = meson_gxl_read_status,
|
|
.suspend = genphy_suspend,
|
|
.resume = genphy_resume,
|
|
},
|
|
};
|
|
|
|
static struct mdio_device_id __maybe_unused meson_gxl_tbl[] = {
|
|
{ 0x01814400, 0xfffffff0 },
|
|
{ }
|
|
};
|
|
|
|
module_phy_driver(meson_gxl_phy);
|
|
|
|
MODULE_DEVICE_TABLE(mdio, meson_gxl_tbl);
|
|
|
|
MODULE_DESCRIPTION("Amlogic Meson GXL Internal PHY driver");
|
|
MODULE_AUTHOR("Baoqi wang");
|
|
MODULE_AUTHOR("Neil Armstrong <narmstrong@baylibre.com>");
|
|
MODULE_LICENSE("GPL");
|