50 lines
1.5 KiB
Plaintext
50 lines
1.5 KiB
Plaintext
* Amlogic Meson8, Meson8b and Meson8m2 Clock and Reset Unit
|
|
|
|
The Amlogic Meson8 / Meson8b / Meson8m2 clock controller generates and
|
|
supplies clock to various controllers within the SoC.
|
|
|
|
Required Properties:
|
|
|
|
- compatible: must be one of:
|
|
- "amlogic,meson8-clkc" for Meson8 (S802) SoCs
|
|
- "amlogic,meson8b-clkc" for Meson8 (S805) SoCs
|
|
- "amlogic,meson8m2-clkc" for Meson8m2 (S812) SoCs
|
|
- reg: it must be composed by two tuples:
|
|
0) physical base address of the xtal register and length of memory
|
|
mapped region.
|
|
1) physical base address of the clock controller and length of memory
|
|
mapped region.
|
|
|
|
- #clock-cells: should be 1.
|
|
- #reset-cells: should be 1.
|
|
|
|
Each clock is assigned an identifier and client nodes can use this identifier
|
|
to specify the clock which they consume. All available clocks are defined as
|
|
preprocessor macros in the dt-bindings/clock/meson8b-clkc.h header and can be
|
|
used in device tree sources.
|
|
|
|
Similarly a preprocessor macro for each reset line is defined in
|
|
dt-bindings/reset/amlogic,meson8b-clkc-reset.h (which can be used from the
|
|
device tree sources).
|
|
|
|
|
|
Example: Clock controller node:
|
|
|
|
clkc: clock-controller@c1104000 {
|
|
compatible = "amlogic,meson8b-clkc";
|
|
reg = <0xc1108000 0x4>, <0xc1104000 0x460>;
|
|
#clock-cells = <1>;
|
|
#reset-cells = <1>;
|
|
};
|
|
|
|
|
|
Example: UART controller node that consumes the clock generated by the clock
|
|
controller:
|
|
|
|
uart_AO: serial@c81004c0 {
|
|
compatible = "amlogic,meson-uart";
|
|
reg = <0xc81004c0 0x14>;
|
|
interrupts = <0 90 1>;
|
|
clocks = <&clkc CLKID_CLK81>;
|
|
};
|